  相信很多相關(guān)行業(yè)人員都見過內(nèi)窺鏡,內(nèi)窺鏡包括插入部,操作部,光導(dǎo)接頭

  I believe many professionals in related industries have seen endoscopes, which include insertion parts, operating parts, and optical connectors

  內(nèi)窺鏡維修成本很高,主要有以下幾個原因:

  The maintenance cost of endoscopes is very high, mainly due to the following reasons:

  精密復(fù)雜的構(gòu)造

  Precise and complex construction

  光學(xué)系統(tǒng)精密:內(nèi)窺鏡的光學(xué)系統(tǒng)是其核心部分之一。例如,物鏡和目鏡(或圖像傳感器)的精度要求極高。為了獲得清晰、準(zhǔn)確的圖像,這些光學(xué)元件需要采用高質(zhì)量的材料,如特殊的光學(xué)玻璃或高精度的 CCD/CMOS 圖像傳感器。這些元件在制造過程中需要精密的加工工藝和嚴(yán)格的質(zhì)量控制,一旦損壞,更換或修復(fù)的成本很高。而且光學(xué)系統(tǒng)的校準(zhǔn)也需要專業(yè)的設(shè)備和技術(shù)人員,其調(diào)試過程復(fù)雜且耗時。

  Precision optical system: The optical system of an endoscope is one of its core components. For example, the precision requirements for objective lenses and eyepieces (or image sensors) are extremely high. In order to obtain clear and accurate images, these optical components require the use of high-quality materials, such as special optical glass or high-precision CCD/CMOS image sensors. These components require precise machining processes and strict quality control during the manufacturing process, and once damaged, the cost of replacement or repair is high. Moreover, the calibration of optical systems also requires professional equipment and technicians, and the debugging process is complex and time-consuming.

  機(jī)械結(jié)構(gòu)精細(xì):內(nèi)窺鏡的機(jī)械結(jié)構(gòu)包括插入部、彎曲部和操作手柄等。插入部要在保證足夠的柔韌性的同時,還要具備良好的抗磨損性和抗壓性,其材料一般是特殊的醫(yī)用高分子材料和金屬材料的復(fù)合結(jié)構(gòu)。彎曲部的關(guān)節(jié)結(jié)構(gòu)復(fù)雜,能實現(xiàn)多角度的靈活彎曲,這些精細(xì)的機(jī)械結(jié)構(gòu)在使用過程中容易出現(xiàn)磨損、變形等問題。而維修時,對這些復(fù)雜機(jī)械部件的拆卸、更換和重新組裝都需要專業(yè)工具和經(jīng)驗豐富的技術(shù)人員,人工成本和零部件成本都很高。

  Fine mechanical structure: The mechanical structure of an endoscope includes an insertion part, a bending part, and an operating handle. The insertion part should not only ensure sufficient flexibility, but also have good wear resistance and compression resistance. Its material is generally a composite structure of special medical polymer materials and metal materials. The joint structure of the curved part is complex and can achieve flexible bending at multiple angles. These delicate mechanical structures are prone to wear and deformation during use. During maintenance, the disassembly, replacement, and reassembly of these complex mechanical components require professional tools and experienced technicians, resulting in high labor and component costs.

  照明系統(tǒng)復(fù)雜:照明系統(tǒng)中的光源裝置通常采用冷光源,如氙燈或高亮度 LED。氙燈本身價格較貴,并且其使用壽命有限,更換氙燈需要專業(yè)的技術(shù)來確保光源的強(qiáng)度和色溫符合要求。LED 光源雖然壽命較長,但如果出現(xiàn)故障,由于其與整個照明系統(tǒng)的集成度較高,維修也需要涉及到電路板、光導(dǎo)纖維等多個部件的檢查和修復(fù),成本相應(yīng)增加。

  The lighting system is complex: The light source devices in the lighting system usually use cold light sources, such as xenon lamps or high brightness LEDs. Xenon lamps themselves are expensive and have a limited lifespan. Replacing a xenon lamp requires professional skills to ensure that the intensity and color temperature of the light source meet the requirements. Although LED light sources have a longer lifespan, if they malfunction, due to their high integration with the entire lighting system, maintenance also requires inspection and repair of multiple components such as circuit boards and optical fibers, resulting in increased costs.

  專業(yè)的維修技術(shù)和設(shè)備

  Professional maintenance techniques and equipment

  技術(shù)要求高:內(nèi)窺鏡維修需要專業(yè)的技術(shù)人員,他們需要經(jīng)過嚴(yán)格的培訓(xùn),熟悉內(nèi)窺鏡的構(gòu)造、原理和各種故障的診斷方法。這些技術(shù)人員不僅要掌握機(jī)械維修技能,還要精通電子電路、光學(xué)系統(tǒng)的維修和調(diào)試。例如,對圖像傳感器的維修需要在無塵環(huán)境下進(jìn)行,以避免灰塵顆粒對成像質(zhì)量的影響,并且要使用專業(yè)的電子檢測設(shè)備來檢測和修復(fù)傳感器的故障。

  High technical requirements: Endoscope maintenance requires professional technicians who have undergone rigorous training and are familiar with the structure, principles, and various diagnostic methods of endoscopes. These technicians not only need to master mechanical maintenance skills, but also be proficient in the maintenance and debugging of electronic circuits and optical systems. For example, the maintenance of image sensors needs to be carried out in a dust-free environment to avoid the impact of dust particles on imaging quality, and professional electronic detection equipment should be used to detect and repair sensor faults.

  專用設(shè)備昂貴:維修內(nèi)窺鏡需要使用一系列專用的設(shè)備,如光學(xué)檢測設(shè)備、精密機(jī)械加工設(shè)備、電子測試儀器等。這些設(shè)備價格昂貴,而且需要定期維護(hù)和更新,以確保其能夠準(zhǔn)確地檢測和修復(fù)內(nèi)窺鏡的故障。例如,用于檢測內(nèi)窺鏡光學(xué)系統(tǒng)成像質(zhì)量的設(shè)備,其精度可以達(dá)到微米級別,能夠檢測出微小的光學(xué)像差和色差,這種高精度設(shè)備的購置和使用成本都很高。

  Expensive specialized equipment: Repairing endoscopes requires the use of a range of specialized equipment, such as optical inspection equipment, precision machining equipment, electronic testing instruments, etc. These devices are expensive and require regular maintenance and updates to ensure accurate detection and repair of endoscope malfunctions. For example, equipment used to detect the imaging quality of endoscopic optical systems can achieve micrometer level accuracy and detect small optical aberrations and chromatic aberration. The purchase and use costs of such high-precision equipment are high.

  配件供應(yīng)有限且價格高

  Limited supply of accessories and high prices

  原廠配件壟斷:很多內(nèi)窺鏡生產(chǎn)廠家對配件供應(yīng)有一定的控制,尤其是一些關(guān)鍵配件,如特殊規(guī)格的光學(xué)元件、專用的機(jī)械部件等。這些原廠配件價格往往較高,而且廠家可能會限制非授權(quán)維修機(jī)構(gòu)獲取配件,使得維修市場的競爭不充分,導(dǎo)致維修成本居高不下。

  Monopoly of original accessories: Many endoscope manufacturers have certain control over the supply of accessories, especially some key accessories such as special specifications of optical components, specialized mechanical parts, etc. These original parts often have higher prices, and manufacturers may restrict unauthorized repair agencies from obtaining parts, resulting in insufficient competition in the repair market and high repair costs.20200408042119178

  配件定制化程度高:內(nèi)窺鏡的許多配件是根據(jù)其特定的型號和規(guī)格定制的,不能與其他品牌或型號的內(nèi)窺鏡通用。這意味著在維修時,很難找到便宜的替代品,必須使用與原內(nèi)窺鏡完全匹配的配件。例如,某一型號內(nèi)窺鏡的活檢通道配件,其尺寸、形狀和材質(zhì)都是根據(jù)該內(nèi)窺鏡的整體設(shè)計來定制的,其他非原廠的通用配件可能無法安裝或無法正常使用,只能購買價格較高的原廠定制配件。

  High degree of customization of accessories: Many accessories of endoscopes are customized according to their specific models and specifications, and cannot be used interchangeably with other brands or models of endoscopes. This means that during repairs, it is difficult to find cheap alternatives and it is necessary to use parts that are completely compatible with the original endoscope. For example, the biopsy channel accessories of a certain model of endoscope are customized based on the overall design of the endoscope in terms of size, shape, and material. Other non original universal accessories may not be able to be installed or used properly, and can only be purchased with higher priced original customized accessories.

  維修后的質(zhì)量檢測嚴(yán)格

  Strict quality inspection after maintenance

  功能檢測全面:內(nèi)窺鏡維修后需要進(jìn)行全面的質(zhì)量檢測,以確保其性能符合醫(yī)療使用標(biāo)準(zhǔn)。這包括光學(xué)性能檢測(如圖像的清晰度、色彩還原度、視野范圍等)、機(jī)械性能檢測(如插入部的柔韌性、彎曲部的靈活度等)和電氣性能檢測(如照明系統(tǒng)的亮度、電路的穩(wěn)定性等)。這些檢測項目需要使用多種專業(yè)設(shè)備,并且檢測過程較為復(fù)雜,增加了維修后的檢測成本。

  Comprehensive functional testing: After repairing the endoscope, a comprehensive quality inspection is required to ensure that its performance meets medical usage standards. This includes optical performance testing (such as image clarity, color reproduction, field of view, etc.), mechanical performance testing (such as flexibility of insertion parts, flexibility of bending parts, etc.), and electrical performance testing (such as brightness of lighting systems, stability of circuits, etc.). These testing projects require the use of various professional equipment, and the testing process is relatively complex, which increases the cost of testing after maintenance.

  消毒和滅菌要求:由于內(nèi)窺鏡用于人體內(nèi)部檢查,維修后的消毒和滅菌是必不可少的環(huán)節(jié)。內(nèi)窺鏡的消毒和滅菌需要嚴(yán)格按照醫(yī)療規(guī)范進(jìn)行,通常采用高溫高壓滅菌、化學(xué)消毒等方法。這些消毒和滅菌過程不僅需要使用專門的設(shè)備和試劑,而且需要對消毒滅菌效果進(jìn)行監(jiān)測,確保內(nèi)窺鏡在再次使用時不會對患者造成感染風(fēng)險,這也在一定程度上增加了維修成本。

  Disinfection and sterilization requirements: As endoscopes are used for internal examination of the human body, disinfection and sterilization after maintenance are essential steps. The disinfection and sterilization of endoscopes need to be strictly carried out in accordance with medical standards, usually using methods such as high-temperature and high-pressure sterilization, chemical disinfection, etc. These disinfection and sterilization processes not only require the use of specialized equipment and reagents, but also require monitoring of disinfection and sterilization effectiveness to ensure that endoscopes do not pose a risk of infection to patients when reused, which also increases maintenance costs to some extent.

  本文由 內(nèi)窺鏡維修 友情奉獻(xiàn).更多有關(guān)的知識請點擊  http://m.483177.com    真誠的態(tài)度.為您提供為全面的服務(wù).更多有關(guān)的知識我們將會陸續(xù)向大家奉獻(xiàn).敬請期待.

  This article is a friendly contribution from endoscope maintenance For more related knowledge, please click http://m.483177.com Sincere attitude To provide you with comprehensive services We will gradually contribute more relevant knowledge to everyone Coming soon.

s
新聞資訊
聯(lián)系我們
  • 公司公司:匠仁醫(yī)療設(shè)備有限公司
  • 匠仁醫(yī)療山東濟(jì)南維修部
  • 聯(lián)系人:樊經(jīng)理
  • 電話:13153199508
  • 地址:山東省濟(jì)南市槐蔭區(qū)美里東路3000號德邁國際信息產(chǎn)業(yè)園6號樓101-2室
  • 匠仁醫(yī)療湖南長沙維修部
  • 聯(lián)系人:李經(jīng)理
  • 電話:13873135765
  • 地址:湖南省長沙市雨花區(qū)勞動?xùn)|路820號恒大綠洲14棟2409室
新聞資訊

樊經(jīng)理:13153199508     李經(jīng)理:13873135765

公司地址:山東省濟(jì)南市槐蔭區(qū)美里東路3000號德邁國際信息產(chǎn)業(yè)園6號樓101-2室  湖南省長沙市雨花區(qū)勞動?xùn)|路820號恒大綠洲14棟2409室

     

魯公網(wǎng)安備 37010402441281號